Use the following tabs to configure the Histogram chart. Click
on each tab name for properties descriptions.
See Also
Histogram Chart: Chart Tab
Properties on the Histogram Chart Tab
Property
|
Description
|
Values
|
Category
|
Indicates whether to display the data
category in Tool Tips.
|
Selected –
category is shown in Tool Tips.
Cleared –
category is not shown in Tool Tips.
|
Frequency
|
Indicates whether to display the frequency
value in Tool Tips.
|
Selected – the
frequency value is shown in Tool Tips.
Cleared – the
frequency value is not shown in Tool Tips.
|
Enable
|
Indicates whether to display Tool Tips when
the cursor moves over data points on the chart.
|
Selected – Tool
Tips are shown when the cursor moves over data points.
Cleared – Tool
Tips are not shown when the cursor moves over data points.
|
Use Series
Color
|
Indicates whether to use the color that is
set for the series (data column) as the color for the associated
Tool Tip. The series color is set on the Data tab.
|
Selected – the
background color of Tool Tips matches the color of the associated
series (data column).
Cleared – the
background color of all Tool Tips is the default color.
|
Decimal
Places
|
Specifies the number of decimal places to
display on the Tool Tips for category and frequency values.
|
Values 0 - 7
|
Specification
Limits:
Not Specified
|
Indicates that the specification limits
(lower specification limit line and upper specification line) will
not appear on the chart.
|
N/A
|
Specification
Limits:
Specified
|
Indicates that the upper specification limit
(USL), lower specification limit (LSL), and target values are the
values that you enter (Constant option) or are retrieved from a
data source (Data Source option).
If you select the Constant option, enter the
values for USL, LSL, and Target.
If you select the Data Source option, click
the Configure Data Source button and select sources for the 3
values.
|
Upper Specification
Limit – the upper limit that a system or process must
operate within.
Lower Specification
Limit – the lower limit that a system or process must
operate within.
Target – the
exact value at which the system or process should optimally
operate.
|
Specification
Limits:
From VisualSPC
Source
|
Indicates that the specification limits are
retrieved from the ShopFloor SPC data source.
|
N/A
|
Normal Curve
Properties:
Calculated
From Data
|
Indicates that mean and standard deviation
values for the normal curve (the bell-shaped curve that indicates
normal distribution) are calculated from the data source (as set on
the Data tab).
|
N/A
|
Normal Curve
Properties:
Specified
|
Indicates that you can either set specific
values for mean and standard deviation or specify the data source
the values can be retrieved from. The values make up the
specifications for the normal curve (the bell-shaped curve that
indicates normal distribution).
|
Constant –
Allows you to enter specific values for Mean and Std Dev.
Data Source –
Allows you to specify a data source for the Mean and Std Dev
values.
|
Normal Curve
Properties:
Display 3 Sigma
and Mean Lines
|
Indicates whether 3 Sigma and Mean lines are
shown on the chart.
|
Selected – +3S,
Mean, and -3S lines appear on the chart.
Cleared – 3
Sigma and Mean lines do not appear on the chart.
|
Histogram Chart: Frequency Axis Tab
Use the Frequency Axis tab to configure the Frequency y-axis for
the Histogram chart. The configuration options are the same as the
Data Axis tab configuration options for most other SPC charts.
Refer to the following for configuration option details:
SPC Charts: Data Axis
Tab
Histogram Chart: Category Axis Tab
Use the Category Axis tab to configure the Data Categories
x-axis for the Histogram chart. The configuration options are the
same as the Subgroup Axis tab configuration options for most other
SPC charts. Refer to the following for configuration option
details:
SPC Charts:
Subgroup Axis Tab