Eliminate Capability Mismatch

(Available with Order Execution Mgt.)


Range Source Eliminate by Capability Mismatch applies a weight to items for which the value of a specified attribute does not match the value of any point within RCO's set of capability points.

The applied weight is a value that:

You entered in the Set Block Weights function block's corresponding parameter.

Set Block Weights assigns to this function block.

Note: A block that applies a zero weight directly eliminates items that fail from the range source.


This function block has the following parameters:



Always Evaluate

Hard, Soft or Breakable.

Controls what happens when the extension eliminates all items in the range source.



All items will remain eliminated. Enter a wait state after the logic script has completed.



Roll back any eliminations made by this extension.



Roll back any eliminations made by this extension that have a danger point value of TRUE (non zero).

Routing modules will first use the danger defined for each individual decision.

However, one of the following may occur instead.







No danger point has been configured for the decision.

The site-wide danger point will be used.



This function block is used in the decision output logic.

The site-wide danger point will be used.



No danger point can be found for a decision.

The decision remains eliminated.

Attribute Name

ID of the attribute to base the comparison on.

Attribute Start Byte

(Optional) An integer that specifies the byte address (offset) of the first byte within the attribute is included in the value comparison.

Attribute Length

(Optional) An integer that specifies the number of bytes, beginning with the Attribute Start Byte, to include in the value comparison.

Region Name

Region where the capability point to be compared with an attribute is assigned.

Capability Point Number

Capability point (Point #1, Point #2, or Point #3) from that region.

Attribute Point ID

(Optional) Text point.

Stores the name of an attribute.

Supercedes Attribute Name.

Note: You can compare the value of an attribute, or the value of a specified number of bytes within an attribute.



Attribute Start Character  is:


Attribute Length is:






The value of the specified bytes, taken as a whole, is compared.




Not specified

A one byte value is compared.


Not specified


Not specified

The binary value of the attribute is compared.

More information

Check Process Capability.

Make further Runtime Region Specifications.

Eliminate and Weight Sources.

RSA function blocks list.