(Available with Order Execution Mgt.)
Description
Record Attribute Ratios adds history data for the currently selected source item to ratio history array points you create or select.
Notes
Add Record Attribute Ratios to the end of any
module where you use the Eliminate Source by Ratio function block to store information about the item
that remains after that elimination.
Example
Eliminate Source by Ratio is in a Resequence Block Module,
Place a Record Attribute Ratios block between that block and the Resequence Range block at the end of that module.
Record Attribute Ratio records only one
item's
history data to the specified points – the item at the range
source head.
Where all item eliminations (by
any and all methods) have been completed.
Insert another function block such as
Select Lowest Weight |
|
Select Source By Age |
before Record Attribute Ratio to insure that the most appropriate item(s) are selected.
If you have criteria to determine which item should be selected in case of a tie, specify that criteria in an RSA function block inserted before the Select block.
Insert Record Attribute Ratio.
Parameters
This function block has the following parameters:
Important: Select the
same array points previously configured for the corresponding
Eliminate Source by Ratio block
you inserted earlier in this logic or output module.
Parameter |
Description |
Attribute Name Array |
Text array point. The names of the selected item's attributes are recorded to elements of this array. |
Attribute Value Array |
Text array point. The values of the selected item's respective attributes are recorded to elements of this array. |
Block Size Array |
Integer (analog) array point. The current number of items selected in a block are recorded to the elements of this array. |
Attribute History Array |
Integer (analog) array point. The current number of items selected for each attribute name/value pair are recorded to this point. |
Eliminate Source By Ratio. |
|
Record selections and rule violations. |
|
RSA function blocks list. |