Basic ACSI conformance statement
|
Client / subscriber |
Server / publisher |
Value / comments |
|
---|---|---|---|---|
Client-server roles |
||||
B11 |
Server side (of TWO-PARTY-APPLICATION-ASSOCIATION) |
- |
C1 |
|
B12 |
Client side of (TWO-PARTY-APPLICATION-ASSOCIATION) |
C1 |
- |
supported |
SCSMs supported |
||||
B21 |
SCSM: IEC 61850-8-1 used |
|
|
supported |
B22 |
SCSM: IEC 61850-9-1 used |
|
|
|
B23 |
SCSM: IEC 61850-9-2 used |
|
|
|
B24 |
SCSM: other |
|
|
|
Generic substation event model (GSE) |
||||
B31 |
Publisher side |
- |
O |
|
B32 |
Subscriber side |
O |
- |
not supported |
Transimission of sampled value model (SVC) |
||||
B41 |
Publisher side |
- |
O |
|
B42 |
Subscriber side |
O |
- |
not supported |
C1 – shall be 'M' if support for LOGICAL-DEVICE model has been declared. O – Optional M – Mandatory |
ACSI models conformance statement
|
Client / subscriber |
Server / publisher |
Value / comments |
|||
---|---|---|---|---|---|---|
If Server side (B11) is supported |
||||||
M1 |
Logical device |
C2 |
C2 |
|
||
M2 |
Logical node |
C3 |
C3 |
|
||
M3 |
Data |
C4 |
C4 |
|
||
M4 |
Data set |
O |
O |
|
||
M5 |
Substitution |
O |
O |
|
||
Reporting |
||||||
M7 |
Buffered report control |
O |
O |
|
||
M7-1 |
sequence-number |
|
|
|
||
M7-2 |
report-time-stamp |
|
|
|
||
M7-3 |
reason-for-inclusion |
|
|
|
||
M7-4 |
data-set-name |
|
|
|
||
M7-5 |
data-reference |
|
|
|
||
M7-6 |
buffer-overflow |
|
|
|
||
M7-7 |
entryID |
|
|
|
||
M7-8 |
BufIm |
|
|
|
||
M7-9 |
IntgPd |
|
|
|
||
M7-10 |
GI |
|
|
|
||
M8 |
Unbuffered report control |
O |
O |
|
||
M8-1 |
sequence-number |
|
|
|
||
M8-2 |
report-time-stamp |
|
|
|
||
M8-3 |
reason-for-inclusion |
|
|
|
||
M8-4 |
data-set-name |
|
|
|
||
M8-5 |
data-reference |
|
|
|
||
M8-6 |
BufIm |
|
|
|
||
M8-7 |
IntgPd |
|
|
|
||
M8-8 |
GI |
|
|
|
||
Logging |
||||||
M9 |
Log control |
O |
O |
|
||
M9-1 |
IntgPd |
|
|
|
||
M10 |
Log |
O |
O |
|
||
M11 |
Control |
M |
M |
|
||
If GSE (B31/B23) is supported |
||||||
|
GOOSE |
O |
O |
|
||
M12-1 |
entry-ID |
|
|
|
||
M12-2 |
DataRefInc |
|
|
|
||
M13 |
GSSE |
O |
O |
|
||
|
Client / subscriber |
Server / publisher |
Value / comments |
|||
If SVC (B41/B42) is supported |
||||||
M14 |
Multicast SVC |
O |
O |
|
||
M15 |
Unicast SVC |
O |
O |
|
||
M16 |
Time |
M |
M |
Time source with required accuracy shall be available |
||
M17 |
File Transfer |
O |
O |
|
||
C2 – shall be 'M' if support for LOGICAL-NODE model has been declared C3 – shall be 'M' if support for DATA model has been declared C4 – shall be 'M' if support for DATA-SET, substitution, Report, Log-Control, or Time model has been declared C5 – shall be 'M' if support for Report, GSE, or SV models has been declared
M – Mandatory O - Optional |
ACSI service conformance statement
ACSI Service Conformance |
AA: TP/MC |
Client / subscriber |
Server / publisher |
Comments |
||
---|---|---|---|---|---|---|
Server (Clause 6) |
||||||
S1 |
ServerDirectory |
TP |
|
M |
|
|
Application association (Clause 7) |
||||||
S2 |
Associate |
|
M |
M |
supported |
|
S3 |
Abort |
|
M |
M |
supported |
|
S4 |
Release |
|
M |
M |
supported |
|
Logical device (Clause 8) |
||||||
S5 |
LogicalDeviceDirectory |
TP |
M |
M |
supported |
|
Logical node (Clause 9) |
||||||
S6 |
LogicalNodeDirectory |
TP |
M |
M |
supported |
|
S7 |
GetAllDataValues |
TP |
O |
M |
not supported |
|
Data (Clause 10) |
||||||
S8 |
GetDataValues |
TP |
M |
M |
supported |
|
S9 |
SetDataValues |
TP |
O |
O |
supported |
|
S10 |
GetDataDirectory |
TP |
O |
M |
supported |
|
S11 |
GetDataDefinition |
TP |
O |
M |
not supported |
|
Data set (Clause 11) |
||||||
S12 |
GetDataSetValues |
TP |
O |
M |
not supported |
|
S13 |
SetDataSetValues |
TP |
O |
O |
not supported |
|
S14 |
CreateDataSet |
TP |
O |
O |
not supported |
|
S15 |
DeleteDataSet |
TP |
O |
O |
not supported |
|
S16 |
GetDataSetDirectory |
TP |
O |
O |
supported |
|
Substitution (Clause 12) |
||||||
S17 |
SetDataValues |
TP |
M |
M |
supported |
|
Setting group control (Clause 13) |
||||||
S18 |
SelectActiveSG |
TP |
O |
O |
not supported |
|
S19 |
SelectEditSG |
TP |
O |
O |
not supported |
|
S20 |
SetSGValues |
TP |
O |
O |
not supported |
|
S21 |
ConfirmEditSGValues |
TP |
O |
O |
not supported |
|
S22 |
GetSGValues |
TP |
O |
O |
not supported |
|
S23 |
GetSGCBValues |
TP |
O |
O |
not supported |
|
Reporting (Clause 14) |
||||||
Buffered report control block (BRCB) |
||||||
S24 |
Report |
TP |
C6 |
C6 |
supported |
|
S24-1 |
data-change (dchg) |
|
|
|
|
|
S24-2 |
qchg-change (qchg) |
|
|
|
|
|
S24-3 |
data-update (dupd) |
|
|
|
|
|
S25 |
GetBRCBValues |
TP |
C6 |
C6 |
supported |
|
S26 |
SetBRCBValues |
TP |
C6 |
C6 |
supported |
|
Unbuffered report control block (URCB) |
||||||
S27 |
Report |
TP |
C6 |
C6 |
supported |
|
S27-1 |
data-change (dchg) |
|
|
|
|
|
S27-2 |
qchg-change (qchg) |
|
|
|
|
|
S27-3 |
data-update (dupd) |
|
|
|
|
|
S28 |
GetURCBValues |
TP |
C6 |
C6 |
supported |
|
S29 |
SetURBCValues |
TP |
C6 |
C6 |
supported |
|
C6 - shall declare support for at least one (BRCB or URCB) |
||||||
Logging (Clause 14) |
||||||
Log control block |
||||||
S30 |
GetLCBValues |
TP |
M |
M |
not supported |
|
S31 |
SetLCBValues |
TP |
O |
M |
not supported |
|
Log |
||||||
S32 |
QueryLogByTime |
TP |
C7 |
M |
not supported |
|
S33 |
QueryLogAfter |
TP |
C7 |
M |
not supported |
|
S34 |
GetLogStatusValues |
TP |
M |
M |
not supported |
|
C7 – shall declare support for at least one (QueryLogByTime or QueryLogAfter) |
ACSI Service Conformance |
AA: |
Client/ |
Server/ |
Comments |
|
---|---|---|---|---|---|
Generic substation event model (GSE) (Clause 14.3.5.3.4) |
|||||
GOOSE-CONTROL-BLOCK |
|||||
S35 |
SendGOOSEMessage |
MC |
C8 |
C8 |
not supported |
S36 |
GetGoReference |
TP |
O |
C9 |
not supported |
S37 |
GetGOOSEElementNumber |
TP |
O |
C9 |
not supported |
S38 |
GetGoCBValues |
TP |
O |
O |
not supported |
S39 |
SetGoCBValues |
TP |
O |
O |
not supported |
GSSE-CONTROL-BLOCK |
|||||
S40 |
SendGSSEMessage |
MC |
C8 |
C8 |
not supported |
S41 |
GetGsReference |
TP |
O |
C9 |
not supported |
S42 |
GetGSSEElementNumber |
TP |
O |
C9 |
not supported |
S43 |
GetGsCBValues |
TP |
O |
O |
not supported |
S44 |
SetGsCBValues |
TP |
O |
O |
not supported |
C-8 shall declare support for at least one (SendGOOSEMessage or SendGSSEMessage) C-9 shall declare support if TP association is available |
|||||
Transmission of sampled value model (SVC) (Clause 16) |
|||||
Multicast SVC |
|||||
S45 |
SendMSVMessage |
MC |
C10 |
C10 |
not supported |
S46 |
GetMSVCBValues |
TP |
O |
O |
not supported |
S47 |
SetMSVCBValues |
TP |
O |
O |
not supported |
Unicast SVC |
|||||
S48 |
SendUSVMessage |
TP |
C10 |
C10 |
not supported |
S49 |
GetUSVCBValues |
TP |
O |
O |
not supported |
S50 |
SetUSVCBValues |
TP |
O |
O |
not supported |
C10 – shall declare support for at least one (SendMSVMessage or SendUSVMessage) |
Control (17.5.1) |
|||||
---|---|---|---|---|---|
S51 |
Select |
|
M |
O |
supported |
S52 |
SelectWithValue |
TP |
M |
O |
supported |
S53 |
Cancel |
TP |
O |
O |
not supported |
S54 |
Operate |
TP |
M |
M |
supported |
S55 |
Command-Termination |
TP |
M |
O |
supported |
S56 |
TimeActivated-Operate |
TP |
O |
O |
not supported |
File Transfer (Clause 20) |
|||||
S57 |
GetFile |
TP |
O |
M |
supported |
S58 |
SetFile |
TP |
O |
O |
not supported |
S59 |
DeleteFile |
TP |
O |
O |
supported |
S60 |
GetFileAttributeValues |
TP |
O |
M |
not supported |
ACSI Service Conformance |
AA: TP/MC |
Client / subscriber |
Server / publisher |
Comments |
|
---|---|---|---|---|---|
Time (5.5) |
|||||
T1 |
Time resolution of internal clock |
|
|
|
Nearest negative power of 2 in seconds |
T2 |
Time accuracy of internal clock |
|
|
|
T0 |
|
|
|
|
|
T1 |
|
|
|
|
|
T3 |
|
|
|
|
|
T4 |
|
|
|
|
|
T5 |
T3 |
Supported TimeStamp resolution |
|
|
|
Nearest value of 2**-n in seconds according to 5.5.3.7.3.3 |
Protocol Implementation Conformance Statement (PICS) for A-Profile support
A-Profile Shortcut |
Profile description |
Client |
Server |
Value/Comment |
---|---|---|---|---|
A1 |
Client/Server A-Profile |
C1 |
C1 |
Client supported |
A2 |
GOOSE/GSE Management A-Profile |
C2 |
C2 |
not supported |
A3 |
GSSE A-Profile |
C3 |
C3 |
not supported |
A4 |
TimeSync A-Profile |
C4 |
C4 |
not supported |
C1 Shall be 'M' if support for any service specified in Table 2 are declared within the ACSI basic conformance statement. C2 Shall be 'M' if support for any service specified in Table 6 are declared within the ACSI basic conformance statement. C3 Shall be 'M' if support for any service specified in Table 9 are declared within the ACSI basic conformance statement. C4 Support for at least one other A-Profile shall be declared (e.g. in A1-A3) in order to claim conformance to IEC 61850-8-1. |
PICS for T-Profile support
T-Profile Description |
Client |
Server |
Value/Comment |
|
---|---|---|---|---|
T1 |
TCP/IP T-Profile |
C1 |
C1 |
Client supported |
T2 |
OSI T-Profile |
C2 |
C2 |
not supported |
T3 |
GOOSE/GSE T-Profile |
C3 |
C3 |
not supported |
T4 |
GSSE T-Profile |
C4 |
C4 |
not supported |
T5 |
TimeSync T-Profile |
O |
O |
not supported |
C1 Shall be 'm' if support for A1 is declared. Otherwise, shall be 'i'. C2 Shall be 'o' if support for A1 is declared. Otherwise, shall be 'i'. C3 Shall be 'm' if support for A2 is declared. Otherwise, shall be 'i'. C4 Shall be 'm' if support for A3 is declared. Otherwise, shall be 'i'. i: out-of-scope. The implementation of the item is not within the scope of this standard. |