Selective printing

Previous chapterNext chapter Show allShow all    Hide allHide all

The control element Print in the alarm information list is used for printing a selective Alarm Information List. All alarms are printed which are currently displayed (note the filter conditions) and irrespective of whether the variables are provided with the Printing option.

The file ALARM_G.FRM is used for formatting the output. The FRM file has three parts:

Example Example

The individual parts are separated by %%. The separation marking must be used only once for the list and the footer.
Formatting example:
Configuration in ALARM_G.FRM

Date: @headdatum

Closed Alarm Information List Demo Project

Time @headdatum o'clock

Text

Date / Time received

Time cleared

Information text

Status text

%%

 

 

 

@DATZEITKOMMT

@ZTGEHT

@TAGNR

@AMELDUNG

%%

 

 

 

 

Page

@seite

 

Printout on the printer

Date: 20.03.1995

Closed Alarm Information List Demo Project

Time: 12:00 o'clock

Text

Date / Time received

Time cleared

Information text

Status text

20.03.1995 13:00:00

 

Information xyz

received

20.03.1995 13:03:59

 

Demo information

on

20.03.1995 13:00:00

13:05:35

Information xyz

cleared

20.03.1995 13:11:23

 

Information xyz

received

20.03.1995 13:03:59

13:12:45

Demo information

off

 

Page

1

 

info Info

Pay attention that you use enough blanks. In doing so, you make sure that long limit texts are also displayed correctly.

Example:

@Registration (blanks up to here)