PFS Switching point preview |
Manual -> Production and Facility Scheduler (PFS) -> Dialogs -> PFS Switching point preview |
![]() ![]() ![]() ![]() |
The Production
& Facility Scheduler
context menu enables users to
access the switching point preview mode.
The switching point preview mode is a powerful diagnosis tool enabling users to check over the PFS configuration. It defines and displays, according to the selected filter criteria, absolute and relative switching points and absolute execution times. Therefore, it enables users to assess the effects of the changes they have made before they actually apply them to the equipment. This preview can also be used to display a history of times. The definition is always performed on the basis of the current configuration.
User events can not be executed in the editor. In the Runtime environment, trigger time points for user events are kept in memory for 14 days at the most; therefore, the history of execution times can only be traced back in time over this period of time.
You can also filter the configured objects, for instance if you only wish to search within a specific schedule.
When you close the dialog by clicking on
OK
, the settings you have
defined are saved, and will remain available until the next time
you open access the dialog.
Search dialog in text fields
The Equipment, Schedule, Variable and Function fields support the use of wildcards for filtering purposes:
fill-in |
Meaning |
---|---|
Text |
The naming have to be Text |
*Text |
The naming have to end with Text |
Text* |
The naming have to start with Text |
T??t |
Any character is possible on second and third place. |
Equipment |
Defines the filter to use with the
equipment you are examining. Only switching points inherent to the
relevant equipment will appear in the preview. |
Schedule |
Defines the filter to use with the
schedule you are examining. Only switching points inherent to the
relevant schedules will be displayed in the preview window. |
Variable |
Defines the filter to be applied to the
variables you are searching. Only switching points linked to
relevant variables and matching the criteria defined in the mask
will be displayed in the preview window. |
Function |
Defines the filter to be applied to the
functions you are searching. Only switching points linked to
relevant functions and matching the criteria defined in the mask
will be displayed in the preview window. |
Filtering of |
This option enables you to select which
data should be used when displaying the preview. |
Switching time points |
This option enables you to define the period of time for which you wish to create a preview. |
|
Select the columns according to which you
wish to sort the information, define the sorting sequence and click
on the button |
|
Starts defining execution times according to the established criteria. If the Recursive option is deactivated, only schedules on the first level are searched. Contains the table with the switching points which are executed throughout the specified period and match the filter criteria. Deactivated switching points or switching points contained in deactivated schedules are highlighted. |