recipef |
Manual -> Report Generator -> Engineering in the Editor -> Report functions -> Recipegroup Manager functions -> recipef |
![]() ![]() ![]() ![]() |
This function displays general data of a recipe of the recipe group manager. These data can freely be positioned in the report. As a help for the definition this function can be selected from the menu entry Format/Functions (or with the right mouse button on the cell).
The following data are available:
Contents |
Comment |
---|---|
name |
Name of the variable |
identiication |
Identification of the variable |
type |
Source type |
unit |
Unit of the variable |
value |
Value for the variable in the recipe |
min |
Minimum of the allowed value range for the variable in this recipe |
max |
Maximum of the allowed value range for the variable in this recipe |
is twert |
If the defined variable does not exist in the selected recipe, the cell is marked with "-". |
Syntax: =variabler(variable name,property)
|
=recipef(value,temperature) |