This function displays variable orientated data of a recipe of the recipe group manager. These data are displayed in form of a table. As a help for the definition this function can be selected from the menu entry Format/Functions (or with the right mouse button on the cell).

The following data are available:

Contents

Comment

name

Name of the variable

identiication

Identification of the variable

type

Source type

unit

Unit of the variable

value

Value for the variable in the recipe

min

Minimum of the allowed value range for the variable in this recipe

max

Maximum of the allowed value range for the variable in this recipe

actual_value

 

Syntax: =recipew(contents,direction)

Example Example

=recipew("name","bottom")