Notes
An added Viewer provides the
parameters included with the 'COMMON' Viewer plus a parameter for
identification.
Values entered for the selected
viewer's parameters override values entered for the 'COMMON'
Viewer. If a parameter value is blank, the 'COMMON' Viewer value is
used.
Select the viewer to be configured.
Available parameters are as follows.
Sync configuration file |
|
Sync files |
|
Delay before copying |
|
Hide CimSync when it starts |
|
Start CimSync at system startup |
Sync configuration file |
Select one of the following.
yes |
Local copy will be synchronized with the deployment server file. |
no |
Local copy will be stand-alone, not synchronized with the deployment server. |
Default |
yes |
Important
The Sync configuration file value, yes or no, in the configuration file that is in each Viewer's local folder enables or disables synchronizing the server's configuration file with that viewer.
To insure that synchronization continues, make sure that Sync configuration file is set to yes in all configuration files that are deployed to the viewer. If a configuration file is deployed to the viewer's local folder with Sync configuration file set to no, the Viewer will no longer look for configuration updates.
The configuration file will have to be manually fetched on the Viewer, the value reset to yes and synchronization restarted , to resume configuration deployment from the server to that viewer. At that time the viewer will only look to the server for a new configuration file; it will not look to see if there is a non-deployed configuration file that might have been placed in its own temporary folder.
Sync files |
Select one of the following.
yes |
Files in the Server's deployment folders will be synchronized with the files in the target folders on the Viewer. |
no |
Files will not be synchronized, even if they are in the deployment folder. |
Default |
yes |
Delay before copying |
Is applied to deployment files
only.
Number |
(Seconds) The default number of seconds CIMPLICITY deployment will wait after a file has been added or updated in the deployment folder before it is synchronized with the viewer. Based on the steps that deployment takes the actual time delay will be: |
|
|
gefdepl.dplcfg |
3x the number entered |
|
Deployment files |
2x the number entered. |
Default |
|
300 |
|
gefdepl.dplcfg |
900 seconds |
|
Deployment files |
600 seconds |
Note: The additional delay is necessary for the temporary file and configuration file deployment. |
Important
The configuration file,
gefdepl.dplcfg, is immediately deployed to the temporary folder
on the Viewer. Once deployed, it will prompt you before it is
copied to the Viewer's installation ...\data directory.
CimView files have additional
parameters in order to insure that updated files do not disrupt
running screen activity. The total deployment time is based on the
value and conditions influencing those parameters and the
CopyDelay parameter.
Applies to both the server and the
viewer as follows.
The value entered is applied in total to each, the server and viewer.
Base number of seconds CIMPLICITY
deployment will wait after a file has been added or updated in the
server's deployment folder before it is synchronized with the
viewer.
Base number of seconds the files
waits in the viewer's temporary folder before it is copied to the
local folder.
Delay before copying Guidelines |
Hide CimSync when it starts |
Select one of the following.
yes |
CimSync runs in the background; the CimSync icon does not display. |
no |
A CimSync icon is placed on the Windows Task bar when CimSync is running.
The icon opens a CimSync report window, which lists the synchronization activity. |
Default |
yes |
Start CimSync at system startup |
Select one of the following.
yes |
CimSync will start up when a Viewer is re-booted, |
no |
CimSync will have to be manually started from the CIMPLICITY Configuration Editor on the Viewer or by double-clicking CimSync exe. |
Default |
yes |
Step 2.5. Identify a selected Viewer's parameters and folders. |