Note: The following fields must be configured in order to access the Global tab.
Select the General tab in the PRT Graphic Display Configuration dialog box.
Select options as follows.
2 |
Select the following options. |
Region |
SCHEDULE |
Attribute |
PRT_ITEM_STATUS |
Operator |
Equals (=) |
Value |
1 |
3 |
Configure a display point. |
Click to the right of the Reset field.
Select New on the Popup menu.
A New Point dialog box opens.
Enter and select the following.
Point ID |
RED_COUNT |
Type |
Virtual |
Class |
Analog |
Click
.The Point Properties dialog box opens.
Select the Virtual tab.
Enter the following.
Initialization |
Initialized |
Initial value |
0 |
Note: This will cause 0 to display if there are no red items, rather than ***.
Click
.Result: The Point Properties dialog box closes; RED_COUNT displays in the Display Point field.