Name | Type | Description |
---|---|---|
AML_Call | Boolean |
Call via alarms administration Only available, if
the limit is an alarm: Read more in the online manual
|
Active | Boolean |
Limit active Active: The
limit is active for the Runtime. Read more in the online manual
|
Alarm | Boolean |
as alarm Active: In
case of a limit violation an entry in the alarm lis is
generated. Read more in the online manual
|
AlarmAcknowledge | Boolean |
to acknowledge Only available, if
the limit is an alarm: Read more in the online manual
|
AlarmDelete | Boolean |
To delete Only available, if
the alarm has to be acknowledged: Read more in the online manual
|
Blinking | Boolean |
Flashing Active:
Dynamic elements linked to this variable start flashing, as soon as
this limit is violated. Read more in the online manual
|
Cel | Boolean |
in CEL Active: In
case of a limit violation an entry in the Chronologic Event List
(CEL) is generated. Read more in the online manual
|
Class | Long |
Alarm class Assignment of an alarm class (max. 65535) for
the limit when used as alarm. Read more in the online manual
|
ClassName | ZT_String_REF | Gets/Sets the alarm class which is linked to a limit. |
Color | ZT_COLOR |
Color Color information for the symbol coloring and the limit color when using the variables in the binary element; the color definition of the alarm texts in the alarm information list occurs in the alarm class definition Read more in the online manual
|
Delay | Long |
Delay time [s] Duration (in seconds) that the limit violation
must be active. The value must be active for the defined duration
(without interruption), in order to trigger the configured actions
of the limit violation. ATTENTION: If
combined with the property "take over flashing from limit", this
property has the following effects in the network: Minimum: 0
|
Function | ZT_FUNCTION |
Function Function, which should be executed
automatically in the Runtime, when the limit is violated. Read more in the online manual
|
Group | Long |
Alarm group Assignment of an alarm group (max. 65535) for
the limit when used as alarm. Read more in the online manual
|
GroupName | ZT_String_REF | Gets/Sets the alarm group of a limit. |
HelpCapture | String |
Help chapter Only available, if
the limit is an alarm: Read more in the online manual
|
HelpFile | ZT_FILE |
Help file Only available, if
the limit is an alarm: Read more in the online manual
|
ID_Parent | Long | This property returns the unique ID of the variable where the limit is linked to. |
Invisible | Boolean |
Invisible Active:
Status is not displayed in the dynamic element "Binary element" or
elements are not displayed if their visibility is controlled by
this variable. Read more in the online manual
|
IsMax | Boolean |
Minimum / Maximum Minimum:
Limit violation when reaching or going below defined limit. Read more in the online manual
|
IsVariable | Boolean |
Dynamic limit active Specifies whether the limit text is fixed or whether it is dynamically determined via a variable. active: The limit is not defined via a fixed technical value assignment but via the technical value of another variable. Default: inactive ATTENTION: If the variable limit changes, so that the current value of the variable is suddenly in the critical range without changing, there will also be a limit violation.
|
LimitValue | Double |
Limit Only available, if
no dynamic limit is defined: Read more in the online manual
|
Boolean |
Active:
Alarm or limit violation (with set option "in CEL") is printed
online. Read more in the online manual
|
|
Simple | Boolean | |
Text | String |
Limit text This text will be shown in the Alarm Message List, the Chronological Event List and/or the alarm status line (depending on the configuration) after a limit violation. Dynamic limit
text: allows to include the current values of other
variables in the limit text of a variable and in the limit text of
reaction matrices. You can also link a fixed text with keywords
from a language table via an index. This leads to some
limitations: These limitations can be circumvented by the extension for long dynamic limit texts. For this, you need to activate Long limit texts CEL and Long limit texts AML. Variable values for dynamic limit texts will then be stored in a separate file. Attention: When using dynamic limit texts, you cannot enter comments.
|
ThresholdValue | Double |
Threshold value A threshold value can be defined that will be
used for clearing a limit violation. This avoids unwanted reactions
due to oscillating numerical values.
|
UserProperty1 | String |
User property 1 In the Runtime the user property defined here can be evaluated in a VBA macro. Read more in the online manual
|
UserProperty2 | String |
User property 2 In the Runtime the user property defined here can be evaluated in a VBA macro. Read more in the online manual
|
Variable | ZT_VARIABLE |
Variable Only available, if
the dynamic limit is active: Read more in the online manual
|