Control elements |
Manual -> Energy Edition -> Command input -> Operating during Runtime -> Picture type Command input -> Control elements |
Show all Hide all |
Name |
Control type |
|
Default |
---|---|---|---|
Action buttons |
Text |
Buttons, which can have an action assigned to them. By clicking in the picture, the assigned action is activated and the picture changes to the step "Release" The button is not shown when: - No action is assigned to the button in the current command interlocking. - The variable, with which the picture was loaded, is the command variable, and the action assigned to the button does not use the command variable as action variable. However, if the action 'Lock' was assigned to the button, it is visible. The button is shown as locked when: - The picture is not in 'Step 1'. - The response variable has set one of the status bits I_KENNUNG(18), OFF(20) or NICHT_AKTUELL(29) and writes the assigned action to the command variable. - The response variable has the status REVISION(9) active and the assigned action writes to the command variable. - The response variable has the status REVISION(9) active and the assigned action is 'Correct'. - The assigned action is 'Release' and the response variable does not have the status Alternativevalue(27) active. - The assigned action is 'Correct' and the value of the response variable matches the switching direction. - The assigned action is 'Replace' and the value of the response variable matches the switching direction. - The response variable has the status REVISION(9) active and the assigned action is 'Replace'. - The assigned action is 'Revision' and the value of the response variable matches the switching direction. |
Action1 Action2 |
RV TTA |
Text |
Name of the response variable |
X |
RV identification |
Text |
Name of the response variable |
X |
Action variable unit |
Text |
Unit of the current action variable. |
X |
Action variable set status |
List |
Defines the status to be set for the action 'Status default' for the switching direction 'None'. The stati are set to the current status and updated when changes occur. Is locked when the active action is not 'Set status'. |
|
Desired direction |
Text |
The switching direction configured for the active action. The texts are documented with the setting 'Switching direction'. Depending on the active action, the following text is shown: Command, revision, correction, replace: Text from limit value, depending on switching direction. Status: On or Off Others: empty |
|
Execute Step 2 |
Button |
Delivers the actions to execution. This control is visible only when the picture is in 'Step 2'. The Control is locked when: - Two handed operation was configured and the key 'Ctrl' is not pressed. - The status REVISION(9) of the response variable is set and the assigned action is 'Command', 'Set value', 'Replace' or 'Correct'. The button was already clicked. |
|
Action variable minimum |
Numerical |
Minimum value of the action variable. Not visible if the action variable is of data type 'String'. |
|
Action variable maximum |
Numerical |
Minimum value of the action variable. Not visible if the action variable is of data type 'String'. |
|
Scrollbars |
Numerical |
Setpoint input with scroll bar Sets the value in the control 'Set value' resp. is set by this value. Not visible if the action variable is of data type 'String'. The Control is locked when: - No action is active. - The picture is not in 'Step 1'. |
|
Set value |
Numerical, Text |
Allows the input of the set value. By clicking the Control, it is switched to edit mode and the setpoint input is possible. The edit mode can be left again with "Enter". The new value is set only after clicking the control 'Execute'. The desired value for the action 'Set value' is provided with this control. The Control is locked when: - The status REVISION(9) of the response variable is set. - No action is active. - The picture is not in 'Step 1'. |
|
RV value |
Text |
Value of the response variable |
X |
RV status |
Text |
Contains the status of the response variable in the short form. |
X |
RV unit |
Text |
Unit of the response variable |
X |
Interlocking text |
Text |
Text of the upcoming interlocking. Text is online language switchable |
|
Unlocking |
|
If an unlockable interlocking is upcoming, it can be unlocked with this button. This control is shown only when the picture is in the step 'Unlock'. The Control is locked when the upcoming interlocking is not unlockable. |
|
Exit |
Button |
Closes the picture without action execution. The button is only visible in a modal picture. This button is important for modal pictures, because it is required to leave the picture in case of an error! |
|
Cancel |
Button |
Aborts the execution of the command input and returns to 'Step 1'. The button is locked when the picture is in 'Step 1'. |
|
Lock list |
List |
Contains the locks that were activated at the response variable. Is locked when no action 'Lock' was configured for the command interlocking. Text is online language switchable |
|
User identification |
Input field |
For entering the user identification for the lock. Is locked when no action 'Lock' was configured for the command interlocking. |
|
Lock code |
Input field |
For entering the user-specific lock code. Is locked when no action 'Lock' was configured for the command interlocking. |
|
Execute lock |
Button |
Activates a lock for the user entered in the Control 'User identification'. Is locked when no action 'Lock' was configured for the command interlocking. This user action is logged in the CEL, if not suppressed by the engineering. |
|
Unlock |
Button |
Removes the lock by the user entered in the user identification. Is locked when no action 'Lock' was configured for the command interlocking. This user action is logged in the CEL, if not suppressed by the engineering. |
|
Run |
Button |
Takes over the value of the Control 'Set value' or 'Set status' This Control is visible only when the picture is in 'Step 1'. The Control is locked additionally to the general lock, when: - The active action is not 'Set status', 'Set value' or 'Correct set value'. - The value in the control 'Set value' for the action variable is invalid. |
|
Comment |
Input field |
Comment about the lock. |
|
Action variable Status |
Text |
Status of the active action variable in short form. |
X |
Action variable Name |
Text |
Name of the active action variable. |
X |
Action variable Identification |
Text |
Identification of the active action variable. |
|
Action variable value |
Text |
Value of the active action variable. |
X |
Active action |
Text |
Name of the active action. |
X |