Home 
  
  
 Change View 
  
  
 Print 
  

Pareto chart properties

Use the following tabs to configure the Pareto chart. Click on each tab name for properties descriptions.

Pareto Chart: Data Tab

The Data tab allows you to configure the data source for the chart.

Properties on the Pareto Data Tab 

Property

Description

Values

Data Browser

The source data for the chart.

Configure Data Source button – opens the Data Source Browser.

Data Columns

A list of the data categories to be shown on the chart. These items are selected in the Data Browser. The color assigned to each item is also shown.

Color – any color available in the system can be assigned to the data column (click the colored box beside the column to change it).

Frequency Column
list box

The data column to assign as a frequency for the chart.

NOTE: When you select a frequency column, the value is automatically removed from the Data Columns list.

Frequency columns as specified in the Data Browser.

Show Fixed Number of Categories

Indicates whether there is a fixed number of categories displayed on the chart.

Selected – There is a fixed number of categories, specified in the adjacent text box (valid values: any number).

Cleared – The categories returned from the data source all appear on the chart.

Show Bar of Remaining Categories

Indicates whether the remaining categories are displayed in one bar on the chart. This check box is available only if the Show Fixed Number of Categories check box is selected.

Selected – The remaining categories are shown in a bar.

Cleared – The remaining categories are not shown.

Line Width

The width of the connector line.

Values 1 through 9 – 1 is the narrowest; 9 is the widest.

Line Style

The style of the connector line.

Solid

Dash Dash

Dot Dot

Dash Dot

Dash Dot Dot

Inter-Bar Gap

The amount of space between bars.

Values 0 - 10 – 0 indicates no space between bars; 10 is the most space between bars.

Bad Data Options:
Bad Data Column

NOTE: Not available for VisualSPC data sources (bad data filtering is set automatically)

Allows you to set a filter on the quality column for data sources that supply a quality column. Set the operator and value according to the bad data value in the column.

Use the Quality Column in conjunction with the Bad Data Rule list box to filter out data.

Column – available columns (dependent on data source).

Operator – mathematical operators (=, <>, >, >=, <, <=).

Value – any ASCII characters (value type is text).

Bad Data Options:
Data Column
Value

NOTE: Not available for VisualSPC data sources (bad data filtering is set automatically)

Allows you to set a filter on the chart's data column. Use in conjunction with the Bad Data Rule list box to filter out data. If a single column data source is used, you can filter on the Quality column only (this field is not available).

Operator – mathematical operators (=, <>, >, >=, <, <=).

Value – any number (value type is numeric).

Bad Data Options:
Bad Data Rule

NOTE: Not available for VisualSPC data sources (bad data filtering is set automatically)

The bad data rule to apply to filter criteria (as set for the chart's data column).

NOTE: `Exclude Sample' is the only bad data option available for attribute charts.

NONE – do not apply a bad data rule.

Exclude Sample – the samples that meet the criteria are excluded during run-time.

Exclude SubGroup – the subgroups that consist of samples that meet the criteria are excluded during run-time

Use SubGroup Mean – samples that meet the criteria are removed from a subgroup, and when they are removed, the mean of the remaining samples (in that subgroup) is calculated and used as a substitute for the excluded samples.

Report Title

Specifies the title that appears on a Quick Report (HTML report) when the data is exported.

Any text.

Chart Image

Indicates whether the chart image is exported when data is exported to an HTML table.

NOTE: Tool Tips will not appear in the exported chart image.

Selected – the image of the chart is exported to an HTML table.

Cleared – the image of the chart is not exported to an HTML table (only the data is exported).

Descriptive Statistics

NOTE: Not
available for Pareto charts.

Indicates whether the chart's descriptive statistics (e.g., LCL, UCL, CL) are exported.

Selected – the chart's descriptive statistics are exported.

Cleared – the chart's descriptive statistics are not exported.

Summary Data

Indicates whether the summary data (e.g., cumulative frequency, cumulative percentage) is exported.

Selected – the chart's summary data is exported.

Cleared – the chart's summary data is not exported.

Raw Data

Indicates whether the raw data is exported.

Selected – the chart's raw data is exported.

Cleared – the chart's raw data is not exported.

Pareto Chart: Chart Tab

The Chart tab allows you to configure the appearance and Tool Tips for the Pareto chart.

Properties on the Pareto Chart Tab 

Property

Description

Values

Outline Color

The color of the outline around bars.

Any color available in the Chart Color dialog box.

3D Effect

The number that indicates the depth of the 3D effect.

Any number from 1 through 50. 1 indicates no 3D effect; 50 indicates the deepest 3D effect.

Transparency

The number that indicates transparency.

A number from 0.0 through 1.0 – 0.0 indicates no transparency; 1.0 is the most transparent.

Show Outline

Indicates whether to display an outline on the bars.

Selected – display an outline on the bars.

Cleared – do not display an outline on the bars.

Draw 3D
check box

Indicates whether to display the bars as three-dimensional.

Selected – bars are three-dimensional. (Default)

Cleared – bars are two-dimensional.

Category

Indicates whether to include the category name in the Tool Tips.

Selected – include category name in Tool Tips.

Cleared – do not include category name in Tool Tips.

Frequency

Indicates whether to include the frequency in the Tool Tips.

Selected – include frequency in Tool Tips

Cleared – do not include frequency in Tool Tips.

Cumulative
Frequency

Indicates whether to include the cumulative frequency in the Tool Tips.

Selected – include the cumulative frequency in Tool Tips.

Cleared – do not include the cumulative frequency in Tool Tips.

Cumulative
Percentage

Indicates whether to include the cumulative percentage in the Tool Tips.

Selected – include the cumulative percentage in Tool Tips.

Cleared – do not include the cumulative percentage in Tool Tips.

Enable

Indicates whether to show Tool Tips when the cursor moves over bars.

Selected – display Tool Tips.

Cleared – do not display Tool Tips.

Use Series
Color

Indicates whether to use a data column's set color as the background color of its associated Tool Tip.

NOTE: The color for the data column is set on the Data tab.

Selected – The data column color will be used for the background color of the associated Tool Tip.

Cleared – the background color of Tool Tips for all data columns is the default color.

Decimal Places

The number of decimal places displayed for values in Tool Tips.

Valid values 0 - 7.

Pareto Chart: Frequency Axes Tab

The Frequency Axes tab allows you to configure the frequency axes options for the Pareto chart.

Properties on the Pareto Frequency Axes Tab 

Property

Description

Values

Axis Color (Frequency Axis)

The color of the tick marks and axis line.

Any color available in the Chart Color dialog box.

Axis Title (Frequency Axis)

The title for the frequency axis.

Enter any text.

Show Title (Frequency Axis)

Indicates whether to display the frequency axis title.

Selected – Display the title.

Cleared – Do not display the title.

Axis Color (Percentage Axis)

The color of the tick marks and axis line.

Any color available in the Chart Color dialog box.

Axis Title (Percentage Axis)

The title for the percentage axis.

Enter any text.

Show Title (Percentage Axis)

Indicates whether to display the percentage axis title.

Selected – Display the title.

Cleared – Do not display the title.

High Limit

The highest value the chart displays.

Enter any number.

Low Limit

The lowest value the chart displays.

Enter any number.

Number of Labels

The maximum number of axis labels.

Enter any number.

Decimal Places

The number of decimal places in axis labels.

0 - 7 decimal places.

Auto Set Limits

Indicates whether high and low limits are based on the specified data.

Selected – Limits are based on data.

Cleared – Limits are not based on data.

Pareto Chart: Category Axis Tab

The Category Axis tab allows you to configure the category axis options for the Pareto chart.

Properties on the Pareto Category Axis Tab 

Property

Description

Values

Rotate Labels

Indicates the orientation of category axis labels.

0 degrees – left to right.

90 degrees – top to bottom.

-90 degrees – top to bottom flipped.

Max. Label
Size

Specifies the maximum label size if the labels are rotated either 90 or -90 degrees.

1 - 1000 characters.

Axis Color

The color of the tick marks and axis line.

Any color available in the Chart Color dialog box.

Axis Title

The title for the axis.

Enter any text.

Show Title

Indicates whether to display the axis title.

Selected – Display the title.

Cleared – Do not display the title.