RtFunction

 

Remarks Properties Methods DynProperties Samples

ED
avaliable
RT
avaliable

Remarks:Top

This object is a zenOn function and contains the most important information about the function.
A function can be accessed by a unique name, that has to be defined for it, or you can run through all functions by its index.

Properties:Top

Actual Client ID
Name ParamString Parent
Server StandBy Type

Methods:Top

CheckIn CheckOut Copy
CreateDynProperty DynPropertiesEnum[GET] DynProperties[GET]
DynProperties[PUT] Get IsCheckedOut
IsDifferent IsLocked Parameter
Start UndoCheckOut  

DynProperties:Top

CFktAlarm 'Alarms : ackn. Flashing' 'Alarms/Groups/Classes'
'Alarms : Activate/deactivate alarmgroup connection' 'Print alarm- or CEL-list' 'Export alarms'
'Open help' 'Reload' 'Language change'
'Index archive' 'Export archive' 'List of active archives'
'Picture switch' 'Focus : Set' 'Show menu'
'Picture : Move center' 'Monitor assign' 'Overview window'
'Picture with index' 'Picture : Return to last'
'Send a Message'
'Authorization in network' 'Switch on/off online printing' 'Switch online printer'
CFktPfsEreigniss 'Login without password' CFktRezept
'Recipegroup Manager' CFktRezeptStd CFktSATBefAktivierung
'Script : execute/select online'
'Report : execute' 'Read dBase file'
'Export data' 'Print actual values' 'Send value to hardware'
'Driver Commands' 'Read time from variable' 'Write time to variable' 'VBA Execute Macro'
'Play sound-file'
'Start program'
'File operations' 'Print a hard-copy'

CFktAlarmTop

Name Type Description
Filter SUBITEM
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Type Long Type of the function

'Alarms : ackn. Flashing'Top

Name Type Description
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

PictSwitch SUBITEM
Type Long Type of the function

'Alarms/Groups/Classes'Top

Name Type Description
Action Long Gets or sets the action that should be executed.

0 → Activate alarms/groups/classes
1 → Deactivate
2 → Toggle
ID Long Internal unique ID of the function.
Index Long With this property you have the opportunity to get/set the alarm group or class.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Type Long Gets or sets the type of alarm selection.

0 → Total alarm administration
1 → Alarms of group
2 → Alarms of class
Type Long Type of the function

'Alarms : Activate/deactivate alarmgroup connection'Top

Name Type Description
GroupName String With this property you have the opportunity to get/set the alarm group.
GroupNr Long With this property you have the opportunity to get/set the alarm group via an index.
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsAdvise Boolean With this property you have the opportunity to activate/deactivate the alarm group connection.
IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Type Long Type of the function

'Print alarm- or CEL-list'Top

Name Type Description
Filter SUBITEM
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Type Long Type of the function

'Export alarms'Top

Name Type Description
Filter SUBITEM
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Type Long Type of the function

'Open help'Top

Name Type Description
CHMFile String
HTMFile String
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Type Long Type of the function

'Reload'Top

Name Type Description
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsAll Boolean
IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Type Long Type of the function

'Language change'Top

Name Type Description
FileDirectory String
FileName String
FontList String
HelpDirectory String
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

MediaDirectory String
Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Type Long Type of the function

'Index archive'Top

Name Type Description
ArvBackup Boolean
ArvName String
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Type Long Type of the function

'Export archive'Top

Name Type Description
Filter SUBITEM
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Type Long Type of the function

'List of active archives'Top

Name Type Description
ArvName String
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Type Long Type of the function

'Picture switch'Top

Name Type Description
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Monitor Long
Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

PictFilter SUBITEM
PictSwitch SUBITEM
Picture String Gets or sets the name of the switching picture.
Type Long Type of the function
WndType Long Returns the picture type.

'Focus : Set'Top

Name Type Description
Focus SUBITEM
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Type Long Type of the function

'Show menu'Top

Name Type Description
ActionType Long Gets or sets the action that should be executed.

0 → Show menu (specified by "MenuName")
1 → Hide menu
2 → Change menu (specified by "MenuName")
3 → If no menu exists, then show menu specified by "MenuName"
FilterInRT Boolean Shows the dialog in the runtime, if set TRUE.
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

MenuName String Gets or sets the name of the menu as string.
Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Type Long Type of the function

'Picture : Move center'Top

Name Type Description
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

MidParameter SUBITEM Parameters for centering and zooming
Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

PictSwitch SUBITEM
Picture String Specifies the GUID of the picture that should be centered and/or zoomed.
Type Long Type of the function

'Monitor assign'Top

Name Type Description
DstNum Long
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

SrcNum Long
Type Long Type of the function

'Overview window'Top

Name Type Description
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

OverviewInfo SUBITEM Properties for the overview window
Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Type Long Type of the function

'Picture with index'Top

Name Type Description
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Type Long Type of the function
Variable String

'Picture : Return to last'Top

Name Type Description
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Templates String
Type Long Type of the function

Top

Name Type Description
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

TimeSpan Long
Type Long Type of the function
VarList SUBITEM

Top

Name Type Description
EMSAlgo String
EMSArea String
EMSIsGas Boolean
EMSNet String
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Type Long Type of the function

Top

Name Type Description
Filter SUBITEM
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Type Long Type of the function

'Send a Message'Top

Name Type Description
Filter SUBITEM Message control settings
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Type Long Type of the function

'Authorization in network'Top

Name Type Description
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Token SUBITEM
Type Long Type of the function

'Switch on/off online printing'Top

Name Type Description
Action Long Sets online printing (e.g. for unmanned stations) to a processing status (switch on, switch off, active/inactive).

0 → Active/Inactive
1 → On
2 → Off
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Type Long Type of the function

'Switch online printer'Top

Name Type Description
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsDialogRT Boolean Displays the printer selection dialog in the runtime, if set TRUE.
IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Printer String Gets or sets the name of the printer.
Type Long Type of the function

CFktPfsEreignissTop

Name Type Description
Filter SUBITEM
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Type Long Type of the function

'Login without password'Top

Name Type Description
Alias String Sets or returns the name of the user for the login.
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Type Long Type of the function

CFktRezeptTop

Name Type Description
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String Gets or sets the name of the recipe that should be executed.
Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Type Long Type of the function

'Recipegroup Manager'Top

Name Type Description
Filter SUBITEM
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Type Long Type of the function

CFktRezeptStdTop

Name Type Description
Filter SUBITEM
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Type Long Type of the function

CFktSATBefAktivierungTop

Name Type Description
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Mode Long
Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Type Long Type of the function

Top

Name Type Description
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

SEAParams String
SwitchingSequence String
Type Long Type of the function

'Script : execute/select online'Top

Name Type Description
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Script String Gets or sets the name of the script that should be executed.
Type Long Type of the function

Top

Name Type Description
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

SetpointSetting String
SubmitAndCloseWnd Long
Type Long Type of the function

'Report : execute'Top

Name Type Description
Filter SUBITEM
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Type Long Type of the function

Top

Name Type Description
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

MacroName String
Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Type Long Type of the function

'Read dBase file'Top

Name Type Description
FileName String Gets or sets the path of the database file that should be read.
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Type Long Type of the function

'Export data'Top

Name Type Description
ExportStruct SUBITEM Defines the export settings
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Type Long Type of the function

'Print actual values'Top

Name Type Description
FormatInfo SUBITEM Defines the parameters for the print
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Type Long Type of the function

'Send value to hardware'Top

Name Type Description
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

SetValue SUBITEM
Type Long Type of the function

'Driver Commands'Top

Name Type Description
Command SUBITEM
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Type Long Type of the function

'Read time from variable' 'Write time to variable'Top

Name Type Description
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Time SUBITEM
Type Long Type of the function

'VBA Execute Macro'Top

Name Type Description
Filter SUBITEM
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Type Long Type of the function

'Play sound-file'
'Start program'Top

Name Type Description
FileName String Gets or sets the path of the program that should be executed.

Hint: Addtitional parameters can be passed with the "FilePar" DynProperty.
FilePar String Gets or sets the parameters for the program that is executed (specified by the "FileName" DynProperty).
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsDialogRT Boolean Displays the program and parameter selection dialog within the runtime, if set TRUE.
IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Type Long Type of the function

'File operations'Top

Name Type Description
ID Long Internal unique ID of the function.
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameter SUBITEM Specifies parameters for the file operations
Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Type Long Type of the function

'Print a hard-copy'Top

Name Type Description
ID Long Internal unique ID of the function.
Info SUBITEM Specifies parameters for the hardcopy
IsActual Boolean

Actual

Only available in network projects:
The function will be executed on the PC on which it was started.

Read more in the online manual

IsClient Boolean

Client

Only available in network projects:
The function will be executed on all clients of the project.

Read more in the online manual

IsServer Boolean

Server

Only available in network projects:
The function will be executed on the server of the project.

Read more in the online manual

IsStandBy Boolean

Standby

Only available in redundant network projects:
The function will be executed on the standby server of the project.

Read more in the online manual

Name String

Name

Unique name of the function.
The name is automatically generated by the system on creating a function, but it can be changed afterwards, as long as the new name is not yet used by another function.
Maximum: 128 characters.
Default: Function_x (where x is a consecutive number).

ATTENTION: This property is not available for language switching.

Read more in the online manual

Parameters ZT_FKTPARAM

Parameter

Transfer parameter(s); depends on the type of function.
Depending on the type of function, the according parameter dialog is opened.

Read more in the online manual

Type Long Type of the function

Samples:Top

'########################################################################'
'# Procedure to change the properties of a function with replacing...   #'
'# -------------------------------------------------------------------- #'
'# In the picture to show there are several linked variables, 	 #'
'# beginning with 'Dummy/Dummy' this string will be replaced with the   #'
'# given parameter 'strDest' and the function will be executed.		 #'
'########################################################################'
Sub ChangeFunction(strName As String, strDest As String)
Dim zFCT As RtFunction
Dim strTemp As String
Dim i As Integer

	Set zFCT = thisProject.RtFunctions.Item(strName)
	If zFCT Is Nothing Then
		MsgBox "A function called: " & strName & " is missing!"
		Exit Sub
	End If
	With zFCT
		For i = 0 To CLng(.DynProperties("PictSwitch.SubstiVar")) - 1
			strTemp = .DynProperties("PictSwitch.SubstiVar[" & i & "].Source")
			strTemp = Replace(strTemp, "Dummy/Dummy", strDest)
			.DynProperties("PictSwitch.SubstiVar[" & i & "].Destination") = strTemp
		Next i
		For i = 0 To CLng(.DynProperties("PictSwitch.SubstiFkt")) - 1
			strTemp = .DynProperties("PictSwitch.SubstiFkt[" & i & "].Source")
			strTemp = Replace(strTemp, "Dummy/Dummy", strDest)
			.DynProperties("PictSwitch.SubstiFkt[" & i & "].Destination") = strTemp
		Next i
	End With
End Sub