The following global parameters are modified on a per-project basis for particular Communications options.
Allen-Bradley Communications |
|
Allen-Bradley DF1 Communications |
|
CCM2 Communications |
|
DDE Communications (As-Is-Local only)) |
|
FloPro/FloNet Communications |
|
Marquee network configuration |
|
Mitsubishi Serial Communication |
|
Mitsubishi TCP/IP Communications |
|
Modbus RTU Communications |
|
Modbus TCP/IP Communications |
|
OMRON Host Link Communications |
|
OMRON TCP/IP Communications |
|
Series 90 TCP/IP Communications (As-Is)) |
|
Series 90 TCP/IP Triplex Communications |
|
Smarteye Communications |
|
SNP Communications |
|
SNPX Communications |
|
Square D SY/MAX Communications |
|
Toyopuc Ethernet Device Communications |
Allen-Bradley Communications
ABI_MAXDEF |
|
ABETH_PLC_POLL_TIMEOUT |
|
ABETH_PLC_REQUEST_TIMEOUT |
|
ABETH_PLC_RESPONSE_TIMEOUT |
|
ABETH_UNSO_QUEUE_SIZE |
Allen-Bradley DF1 Communications
ABDF1_<PORT>_USESPFP |
CCM2 Communications
<PORT>_TURN_AROUND_DELAY |
DDE Communications (Legacy)
DDE_UNAVAIL_ON_ILLEGAL_VAL |
FloPro/FloNet Communications
DC_RETRY_ONE_DEVICE |
|
FLOPRO_RESPONSE_TIMEOUT |
|
FLOPRO_STATIC_MODEL |
Marquee network configuration
TSERV_<PORT> |
|
TSERV_<COM> |
Note: Other Marquee global parameters are in the main list.
Mitsubishi Serial Communication
COM<PORT>_TO |
Mitsubishi TCP/IP Communications
DC_CONNECT_MS |
|
DC_TCP_POLL_MS |
|
DCQ_CONNECT_URETRY_CNT |
|
DCQ_DEAD_TIME |
|
MMAX_SYNC_TICKS |
|
MSYNC_TICKS |
|
<PORT>_DC_CONNECT_MS |
|
<PORT>_DC_TCP_POLL_MS |
|
<PORT>_DCQ_DEAD_TIME |
|
<PORT>_MSYNC_TICKS |
Modbus RTU Communications
MB_COMM_TIMEOUT |
|
MDBC |
Modbus TCP/IP Communications
<DEVICE>_READ_REQUEST_TIMEOUT |
|
<DEVICE>_REQ_RETRY |
|
<DEVICE>_TIMEOUT_RETRY_DELAY |
|
DeviceId_CONN_SECONDARY |
|
DeviceId_CONSERVES_CONN |
|
DeviceId_ONE_COIL_WRITE |
|
DeviceId_ONE_REG_WRITE |
|
MBETH_ASYNC_CONNECTION |
|
MBETH_DISABLE_IO_ERRLOG |
|
MBETH_DISABLE_UNSO_DATA |
|
MBETH_ENABLE_PROTOCOL_DEBUG |
|
MBETH_READ_REQUEST_TIMEOUT |
|
MBETH_REQ_MILLISECOND_TIMEOUT |
|
MBETH_REQ_RETRY |
|
MBETH_REQ_TIMEOUT |
|
MBETH_TIMEOUT_RETRY_DELAY |
|
MBETH_UNSO_DATA_QUEUE_SIZE |
|
<PORT>_ASYNC_CONNECTION |
|
<PORT>_DISABLE_IO_ERRLOG |
|
<PORT>_DISABLE_UNSO_DATA |
|
<PORT>_ENABLE_PROTOCOL_DEBUG |
|
<PORT>_READ_REQUEST_TIMEOUT |
|
<PORT>_REQ_MILLISECOND_TIMEOUT |
|
<PORT>_REQ_RETRY |
|
<PORT>_REQ_TIMEOUT |
|
<PORT>_TIMEOUT_RETRY_DELAY |
|
<PORT>_UNSO_DATA_QUEUE_SIZE |
OMRON Host Link Communications
COM<PORT>_TO |
|
OMRON_MAX_BUFFER_SIZE |
OMRON TCP/IP Communications
OMRON_MAX_BUFFER_SIZE |
|
<PORT>_OMRON_SA1 |
|
<PORT>_OMRON_SERVICE |
|
<PORT>_OMRON_SNA |
|
<PORT>_TO |
Series 90 TCP/IP Communications (As-Is)
GMR_NO_MASTER |
|
GMR_SKIP_L_DOMAIN |
|
GMR_WRITE_ALL |
|
HCT_SKIP_L_DOMAIN |
|
UNSO_TX_AREA_<n> |
Series 90 TCP/IP Triplex Communications
<DEVICE>_MAX_POLL_MSG |
|
<DEVICE>_MAX_REQUEST_CACHE |
|
<PORT>_ALLOW_MULTIMSG |
|
<PORT>_DISABLE_KEEPALIVE |
|
<PORT>_MAX_CACHE |
|
<PORT>_MAX_POLL_MSG |
|
<PORT>_MAX_REQUEST_CACHE |
|
S90TCP_ALLOW_MULTIMSG |
|
S90TCP_ALLOW_UNSO |
|
S90TCP_DC_BIT_REVERSE |
|
S90TCP_<DEVICE_ID>_IS_SE |
|
S90TCP_DISABLE_KEEPALIVE |
|
S90TCP_MAX_CACHE |
|
S90TCP_MAX_POLL_MSG |
|
S90TCP_MAX_REQUEST_CACHE |
|
S90TCP_RECONNECT_DELAY |
Smarteye Communications
<PORT>_LOG_WARNING |
|
<PORT>_MODE |
|
<PORT>_POLL_LIMIT |
|
<PORT>_RESTART_SEA |
|
<PORT>_SEA_HANDSHAKE_TIMEOUT |
|
SE_LABEL_LEN |
|
SEA_HANDSHAKE_TIMEOUT |
SNP Communications
SNP_SEND_BREAK |
|
SNP_IDLE_TIME |
SNPX Communications
<DEVICE>_VALIDATE |
|
SNPX_BROADCAST_TIME |
|
SNPX_VALIDATE |
Square D SY/MAX Communications
SYMAX_<PORT>_WORD_SWAP |
Toyopuc Ethernet Device Communications
<PRCNAM>_CONNECTION_TIMEOUT |
|
<PRCNAM>_READ_WRITE_TIMEOUT |
|
<PORT>_BIND_ADDR |